These are very top quality 45 degree speed increasing hand-pieces with an external water supply, we absolutely love them.

We really believe that all dentists should have access to at least one 45 degree speed increasing hand-piece.

Of course to get the maximum benefits from a speed increasing hand-piece you would want access to a micromotor so that you can enjoy the improved torque and performance.

The 45 degree handpiece is especially useful for sectioning teeth for extractions and can be done safely when used with an external water supply.

Handpiece club

When you buy one of our handpiece club products you are not just buying the hand-piece but also our service guarantee.

As you all know hand-pieces require maintenance and no matter the brand (or oiling regimen) they will often seize after 6-9 months. Sometimes they last longer, sometimes shorter but it will always occur.

This is because the bearings inside the hand-pieces are classed as a consumable item. They are actually rarely covered under manufacturers warranties. Also when you send your hand-piece for repair they are often repaired with a generic low quality bearing that is not designed for your hand-piece.

We think it’s time to stop cursing the repair of handpieces and instead prepare for it. We can change a bearing quickly (with a high quality compatible bearing) and get it straight back to you or we will simply replace the hand-piece if the repair is more involved. We know that chair time is so expensive in dentistry and we are fully committed to keeping your equipment working!

So

When you buy a hand-piece from us we will automatically enrol you into our hand-piece maintenance club for 1 year. This means there will be no charges for repairs or replacements throughout the first year. You only pay for postage to us.

At the end of the first year you can choose to sign up for our continued maintenance plan which is priced starting at £8 per hand-piece per month (depending on model and number of handpieces) and, again, includes all repairs or replacements. This works out as a lower annual cost than the average price of a single repair**.

Please note our maintenance plans are only available for hand-pieces purchased from Hand-piece Club.

** Finally please note that hand-piece club is a club. We expect customers to look after their hand-pieces and oil them regularly as part of the agreement. If we feel that there has not been a fair usage of the service we provide we reserve the right to increase the cost of maintenance club subscriptions or even refuse subscriptions in extreme cases.

Materials

Shipping & Returns

Dimensions

Care Instructions

Maintenance and Safe Use of Speed Increasing Handpieces
Introduction
Speed increasing handpieces are essential tools in dental practices, designed to enhance precision and efficiency during procedures. Proper maintenance and safe use are crucial for ensuring the longevity of the handpieces and the safety of both the operator and the patient.
Maintenance Instructions
1. Cleaning, Lubrication, and Purging after each use:
o Cleaning: Use a brush and deionised water to clean the external surfaces of the handpiece only. Avoid soaking the handpieces in water or chemicals as this can lead to corrosion.
o Lubrication: Apply lubricant to the drive air tube and the moving parts as recommended by the manufacturer. Oiling the handpiece prior to autoclaving is essential to promote the smooth running of gears and bearings. Failing to do so can significantly impair performance and reduce lifespan as well as cause overheating.
o Purging: The handpiece must be purged of excess oil before autoclaving. Failure to purge excess oil can cause the formation of a slurry during the autoclaving process. This slurry can lead to overheating and premature failure of gears and bearings during use.
2. Sterilization:
o Autoclaving: After cleaning, lubrication, and purging, place the handpiece in an autoclave pouch and sterilize it in an autoclave. Follow the manufacturer's guidelines for temperature and cycle duration.
o Avoid Chemical Sterilants: Do not use chemical sterilants unless specifically recommended by the manufacturer, as these can damage the internal components.
3. Periodic Maintenance:
o Inspection: Regularly inspect the handpiece for signs of wear and tear, such as cracks or loose parts.
We would typically expect our speed increasing bearings to last between 6-12 months dependent on maintenance protocol and usage. Proper maintenance can significantly improve that duration however it is important be aware that speed increasing handpiece have significantly higher maintenance demands and costs than high speed turbines.
Safe Use Instructions
1. Pre-Use Checks:
o Clinician’s Responsibility: It is the clinician's responsibility to ensure the safe function of each handpiece prior to use on a patient.
o Visual Inspection: Before each use, visually inspect the handpiece for any damage or abnormalities.
o Function Test: Run the handpiece through for 30 seconds to ensure there are no signs of bearing failure such as excessive vibration, noise, or heat. Check that burs rotate properly and about their central axis.
o Initial Heat Dissipation: Be aware that there can be excess heat when the handpiece is first used post-autoclaving as the gears engage and any debris is cleared. Ensuring this excess heat has dissipated prior to use on a patient is essential.
2. Proper Handling:
o Grip and Control: Hold the handpiece with a firm grip to maintain control during use. Avoid applying excessive force, which can damage both the handpiece.
o Avoid Dropping: Handle the handpiece carefully to avoid dropping it, as impacts can misalign the internal components.
3. Operational Precautions:
o Use the Correct Burs: Ensure the burs used are compatible with the handpiece and are properly inserted and secured.
o Speed Settings: Operate the handpiece at the recommended speed settings for different procedures to prevent excessive wear and potential injury.
o Avoid Soft Tissue Contact: Always ensure that the head of the handpiece is not in contact with the patient’s soft tissues, as the handpiece can generate heat and cause burns.
o Bearing Failure Vigilance: Be aware that often, when a speed increasing handpiece bearings fail, the bur will continue to cut, however, excess heat will be generated. Be vigilant for other signs of bearing failure to avoid overheating, which can cause damage to both the operator and the patient.
4. Post-Use Protocol:
o Immediate Cleaning: After use, immediately clean the handpiece to remove debris and prevent build-up.
o Storage: Store the handpiece in a clean, dry place. Use protective caps or cases to prevent contamination and damage.
Additional Tips
• User Training: Ensure all operators are properly trained in the use and maintenance of speed increasing handpieces.
• Manufacturer’s Manual: Always refer to the manufacturer's manual for specific instructions and recommendations for your particular model.
• Record Keeping: Maintain a log of maintenance and sterilization procedures to track the handpiece's condition and service history.

View full details
delivery--v1

UK Delivery Within 5 Working Days

Your orders are shipped with Fedex and usually arrive much quicker. We prefer to under promise and overdeliver however! Orders over £100 ship for free.

external-delivery-box-shopping-online-kmg-design-detailed-outline-kmg-design

Unrivalled Value

We are market disrupters: no reps, no trade shows, no course sponsorship, no freebies. All this means consistently better prices for our customers.

gift--v1

Online Customer Service

We offer super responsive online support that we are really proud of. Emailing us is the most efficient way for us to help you

external-headphone-devices-icongeek26-glyph-icongeek26-1

Curated Range

No need to spend valuable time scrolling through page after page of iterations of the same product. We've done the work hard for you; we would'nt use it, we wont sell it!

external-headphone-devices-icongeek26-glyph-icongeek26-1

EU Delivery 2 - 11 Days

Orders from the EU will be delivered, duty paid, via FEDEX. No taxes or duties to pay once your order arrives!

Notify Me When Available

Fill in the required details to get notified when the product is back in stock.